Active Power Filter
Your Professional Active Power Filter Supplier
The company has a professional production and research and development base in hebei province. The total factory area is 100,000 square meters, and the transportation is very convenient. It has strong technical research and development capabilities and has won 56 national patents. Our product include dry type transformer / oil immersed type transformer / cubicle-type substation / high and low voltage switch cabinet / ring main unit / ring box / low voltage distribution box / instrument / capacitance, reactance, instrument transformer / schneider licensing series.
Why Choose Us
Quality Assurance
The company strictly implements standards such as ISO9001 international quality management system, ISO14001 environmental management system and OHSAS18001 occupational health and safety management system, and has established a perfect management system.
OEM/ODM Solutions
When you share your requirements, our engineers will deliver customized solutions that are both faster and more efficient, tailored specifically to your needs.
Production Equipment
The company's products have complete qualifications and are equipped with advanced production and testing equipment such as CNC turret punch press, CNC shearing machine, CNC bending machine, laser cutting machine, fully automatic copper bar processing machine, fully automatic transformer test bench, pouring and drying.
Production Market
The company focuses on the Russian and Middle Eastern markets as well as Southeast Asia, and is currently completing cooperation with companies in Italy and Uzbekistan.

Multifunctional: Harmonic, reactive power and imbalance compensation
Harmonic Elimination Range: 2nd~50th order (Selectable)
High harmonic filtering rate: Up to 98%
Excellent reactive compensation: High speed, Precise (-0.99 ≤ PF ≤ 0.99), Step-less, Bi-directional (capacitive and inductance) compensation
Excellent imbalance correction: Both negative and zero sequence, mitigates neutral current
Wide input voltage & frequency range: Adapts to tough electrical environments Low thermal loss and high efficiency
High stability: Infinite impedance to grid, avoids harmonic resonance problems
Flexible application: Modular design, embedded in standard or customized cabinet
Easy installation and maintenance: Plug-in installation for APF module replacement and expansion
Wide capacity range: 30~750 A for a single cabinet, up 10 cabinets in parallel
Environmental adaptability: -10~55°C ambient temperature, compatible with diesel generator
Complete protection: Grid Over/Under voltage, APF over current, over temperature, and more.
Specification
|
|
ZS APF3(4) -30A/400V |
ZS APF3(4) -50A/400V |
ZS APF3(4) -75A/400V |
ZS APF3(4) -100A/400V |
|
Rated Voltage (V) |
360~420 |
|||
|
Rated Frequency (Hz) |
50/60(Automatic Frequency Sweeping) |
|||
|
Frequency Skew |
±5% |
|||
|
Rated Compensation Current |
30 |
50 |
75 |
100 |
|
Maximum Reactive Power Output |
30 |
50 |
75 |
100 |
|
Overall Efficiency Of The Equipment |
>97% |
|||
|
Filtering Capacity |
THDi<4% |
|||
|
Filtering Range |
2~50 Times |
|||
|
Dynamic Response Time |
100μS |
|||
|
Complete Response Time |
10ms |
|||
|
Noise (DB) |
<65 |
|||
|
Protection Level |
IP20 |
|||
|
Overvoltage Protection |
士10% |
|||
|
Overheat Protection |
IGBT:70°℃ Other:80℃ |
|||
|
Short-Circuit Protection |
Have |
|||
|
Protective Earthing |
Have |
|||
|
Automatic Current Limiting Protection |
30 |
50 |
75 |
100 |
Types Of Active Power Filter
Active current source filter
This type of active filter is used to correct the power factor and compensate harmonic currents in a specific load.
01
Voltage source active filters
This type of active filter is used to improve the quality of the electrical voltage supplied by the power grid.
02
Series active filter
This type of active filter is used to mitigate harmonics and other voltage fluctuations in a specific load.
03
Shunt active filter
This type of active filter is used to mitigate harmonics and other voltage fluctuations throughout the electrical network.
04
Adaptive active filters
These filters use a control algorithm that can adapt to changes in harmonic distortion in the power system, allowing more efficient and accurate filtering of harmonic frequencies.
05
The active power filter detects the load current through the current transformer, and calculates through the internal DSP, extracts the harmonic components in the load current, and then sends it to the internal IGBT through the PWM signal to control the inverter to generate a harmonic current with the size of the load. Equal and opposite harmonic currents are injected into the power grid to achieve the purpose of filtering.
The function of the command current detection circuit is mainly to separate the harmonic current component and the fundamental wave reactive current from the load current, and then reverse the polarity to generate the command signal of the compensation current. The function of the current tracking control circuit is to calculate the trigger pulse of each switching device of the main circuit according to the compensation current generated by the main circuit, and this pulse acts on the main circuit after the driving circuit. In this way, the power supply current only contains the active component of the fundamental wave, so as to achieve the purpose of eliminating harmonics and performing reactive power compensation. According to the same principle, the active power filter can also compensate the negative sequence current component of the asymmetric three-phase circuit.
The main circuit of the active power filter is generally composed of a PWM inverter. According to the different energy storage elements on the DC side of the inverter, it can be divided into voltage-type active filters (energy-storage elements are capacitors) and current-type active filters (energy-storage elements are inductors). The voltage-type active filter needs to control the capacitor voltage on the DC side during operation, so that the voltage on the DC side remains unchanged, so the output of the AC side of the inverter is a PWM voltage wave. The current-type active filter needs to control the inductor current on the DC side during operation, so that the current on the DC side remains unchanged, so the output of the AC side of the inverter is a PWM current wave. The advantages of the voltage-type active filter are that the loss is less and the efficiency is high. The current will produce a large loss in the internal resistance of the inductor.

Application of Active Power Filter
Communications Industry
The communications industry is experiencing a substantial increase in UPS equipment capacity as data centers continue to expand in scale. Research indicates that the primary harmonic sources in telecom low-voltage distribution systems—including UPS units, switching-mode power supplies, and variable-frequency air conditioning systems—not only generate significant harmonic distortion but also exhibit exceptionally high displacement power factors.
Petrochemical Industry
The petrochemical manufacturing sector faces growing harmonic pollution challenges in power distribution systems due to the widespread adoption of variable frequency drives (VFDs) for pump operations. Most conventional VFDs utilize 6-pulse rectification technology, generating characteristic 5th, 7th, and 11th order harmonics during operation.
Chemical fiber industry
The chemical fiber manufacturing industry extensively employs electric melting heating systems due to their superior process advantages. This technology directly channels electrical energy into glass tank furnaces via electrodes, delivering enhanced melting efficiency, improved glass quality, extended furnace lifespan, and reduced energy consumption.
Steel Industry
In the steel and medium-frequency heating industries, the operation of key equipment such as medium-frequency furnaces, rolling mills, and arc furnaces often leads to severe power quality issues. These nonlinear loads not only frequently trigger overload protection in capacitor compensation cabinets but also cause abnormal heating in transformers and power lines, along with unexpected fuse failures.
Automotive Manufacturing
In the automotive manufacturing industry, welding equipment serves as a critical process asset. However, its stochastic, instantaneous, and high-impact operation poses significant challenges to power distribution systems.
Shipping







